Availability: | |
---|---|
Quantity: | |
Wireless Battery Par9
Prowalls
Static Lights
Description
Wireless Battery Par9 is a very Classic and sucessfull uplight, Wireless DMX, Battery powered, Remote Control, 9x18W RGBWA-UV 6-in-1 bright LEDs, Fast charging for frequent use, 8-12 working hours, lightweight and easy to operate with a carry handle and kickstand for uplighting, staging, events, productions and any mobile application.
Features
*9x18W RGBW-UV 6-in-1 LEDs
*Wireless, Battery powered, Remote Control
*8-12 hours of operation at full and a quick 3 hours full charging time for frequent use
*Lightweight, 10pcs in one rechargeable flight case
Description
Wireless Battery Par9 is a very Classic and sucessfull uplight, Wireless DMX, Battery powered, Remote Control, 9x18W RGBWA-UV 6-in-1 bright LEDs, Fast charging for frequent use, 8-12 working hours, lightweight and easy to operate with a carry handle and kickstand for uplighting, staging, events, productions and any mobile application.
Features
*9x18W RGBW-UV 6-in-1 LEDs
*Wireless, Battery powered, Remote Control
*8-12 hours of operation at full and a quick 3 hours full charging time for frequent use
*Lightweight, 10pcs in one rechargeable flight case
Specification
SOURCE
9x18W RGBW-UV 6-in-1 LEDs
80,000 Hours LED Lifetime (May vary depending on different factors)
FUNCTION
9x18W RGBW-UV 6-in-1 LEDs
Wireless, Battery powered, Remote Control
8-12 hours of operation at full and a quick 3 hours full charging time for frequent use
Awesome color mixing
Lightweight, 10pcs in one rechargeable flight case
Electronic Dimmer and Shutter/Strobe
Built-in Automated Programs
CONTROL & CONNECTIONS
(2) DMX Channel Modes (6/10 channels)
LCD Menu Display
3pin DMX In/Out
PowerCON Power In
DMX512, Auto run, Sound, Master/Slave
THERMAL & ELECTRICAL
162W max Power Consumption
Input voltage: 100-240V AC/50-60 Hz
APPROVALS / RATINGS
CE | RoHs Compliant | IP20
SIZE / WEIGHT
9.8" (250mm) Length
5.1" (130mm) Width
9.8" (250mm) Height
9.9 lbs (4.5 kg) Weight
Specification
SOURCE
9x18W RGBW-UV 6-in-1 LEDs
80,000 Hours LED Lifetime (May vary depending on different factors)
FUNCTION
9x18W RGBW-UV 6-in-1 LEDs
Wireless, Battery powered, Remote Control
8-12 hours of operation at full and a quick 3 hours full charging time for frequent use
Awesome color mixing
Lightweight, 10pcs in one rechargeable flight case
Electronic Dimmer and Shutter/Strobe
Built-in Automated Programs
CONTROL & CONNECTIONS
(2) DMX Channel Modes (6/10 channels)
LCD Menu Display
3pin DMX In/Out
PowerCON Power In
DMX512, Auto run, Sound, Master/Slave
THERMAL & ELECTRICAL
162W max Power Consumption
Input voltage: 100-240V AC/50-60 Hz
APPROVALS / RATINGS
CE | RoHs Compliant | IP20
SIZE / WEIGHT
9.8" (250mm) Length
5.1" (130mm) Width
9.8" (250mm) Height
9.9 lbs (4.5 kg) Weight
Safety Precautions
● To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.
● Do not spill water or other liquids into or on to your unit.
● Be sure that the local power outlet match that of the required voltage for your unit.
● Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
● Disconnect from main power before making any type of connection.
● Do not remove the cover under any conditions. There are no user serviceable parts inside.
● Never operate this unit when it‟s cover is removed.
● Never plug this unit in to a dimmer pack.
● Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
● Do not attempt to operate this unit, if it becomes damaged.
● This unit is intended for indoor use only; use of this product outdoors voids all warranties.
● During long periods of non-use, disconnect the unit‟s main power.
● Always mount this unit in safe and stable matter.
● Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from unit.
● Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See “Cleaning” for details.
● Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
● The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
● Fuse standard is 2A/250V
● Grounded using yellow/green line
● The ambient temperature must always be under +35° C
Set Up
Power Supply: Before plugging your unit in, be sure the source voltage in your area matches the required voltage for your light is workable in 100-220V/50~60Hz. Because line voltage may vary from venue to venue, you should be sure your unit voltage matches the wall outlet voltage before attempting to operate you fixture.
Operating Instructions
Operating Modes: You can use the LED PAR LIGHT in 5 ways:
● Sound activation – The unit will activated by the sound signal.
● Static display – The unit will display the color in static way.
● Auto Mode -The unit will automatically chase through the different patterns.
● DMX control mode -This function will allow you to control the lighting with a standard DMX 512 controller.
● Battery powered – This function will allow you to control the lighting independently without any DMX cable
DMX Mode: Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs. This function also allows you to use your fixtures as pattern changing lights.
1. This function will allow you to control each individual fixtures traits with a standard DMX 512
controller.
2. The LED PAR LIGHT use 6/10 DMX channels to operate. Please see “DMX channel and Functions” for the DMX traits.
3. To run your fixture in DMX mode, plug in the fixture via the XLR connections to any standard DMX controller. Set your desired DMX address following the setup specifications that come with your DMX controller.
4. The unit can automatically recognize the DMX signal once the DMX connection is done.
DMX Linking:
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Safety Precautions
● To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.
● Do not spill water or other liquids into or on to your unit.
● Be sure that the local power outlet match that of the required voltage for your unit.
● Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
● Disconnect from main power before making any type of connection.
● Do not remove the cover under any conditions. There are no user serviceable parts inside.
● Never operate this unit when it‟s cover is removed.
● Never plug this unit in to a dimmer pack.
● Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
● Do not attempt to operate this unit, if it becomes damaged.
● This unit is intended for indoor use only; use of this product outdoors voids all warranties.
● During long periods of non-use, disconnect the unit‟s main power.
● Always mount this unit in safe and stable matter.
● Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from unit.
● Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See “Cleaning” for details.
● Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
● The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
● Fuse standard is 2A/250V
● Grounded using yellow/green line
● The ambient temperature must always be under +35° C
Set Up
Power Supply: Before plugging your unit in, be sure the source voltage in your area matches the required voltage for your light is workable in 100-220V/50~60Hz. Because line voltage may vary from venue to venue, you should be sure your unit voltage matches the wall outlet voltage before attempting to operate you fixture.
Operating Instructions
Operating Modes: You can use the LED PAR LIGHT in 5 ways:
● Sound activation – The unit will activated by the sound signal.
● Static display – The unit will display the color in static way.
● Auto Mode -The unit will automatically chase through the different patterns.
● DMX control mode -This function will allow you to control the lighting with a standard DMX 512 controller.
● Battery powered – This function will allow you to control the lighting independently without any DMX cable
DMX Mode: Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs. This function also allows you to use your fixtures as pattern changing lights.
1. This function will allow you to control each individual fixtures traits with a standard DMX 512
controller.
2. The LED PAR LIGHT use 6/10 DMX channels to operate. Please see “DMX channel and Functions” for the DMX traits.
3. To run your fixture in DMX mode, plug in the fixture via the XLR connections to any standard DMX controller. Set your desired DMX address following the setup specifications that come with your DMX controller.
4. The unit can automatically recognize the DMX signal once the DMX connection is done.
DMX Linking:
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.